.png)
S.U.R.&R AC412L 1/2" Low Side In-Line Service Port Valve: Enhance Your AC System
Maintaining and repairing your vehicle's air conditioning system is crucial for a comfortable driving experience. The S.U.R.&R AC412L 1/2" Low Side In-Line Service Port Valve is a critical component for AC system maintenance, allowing for efficient and accurate servicing. This valve is designed to provide easy access to the low-pressure side of your AC system, making it simpler to diagnose issues, recharge refrigerant, and perform other essential tasks. By investing in a high-quality service port valve like the AC412L, you're ensuring that your air conditioning system receives the best possible care, leading to improved performance and longevity. Keep your cool with the AC412L, available now at Dealershop USA.
This is a vital component for any automotive repair shop or DIY enthusiast looking to maintain and service AC systems effectively. S.U.R.&R, a trusted name in automotive fluid line repair solutions, designed the AC412L with efficiency and durability in mind. The in-line design ensures seamless integration into existing systems. This ensures minimal disruption during installation and provides a secure and reliable connection for years to come. The AC412L is engineered specifically for the low side, providing accurate pressure readings and facilitating safe refrigerant handling. Proper pressure readings are essential for accurate diagnostics. This precision contributes to efficient repairs and helps prevent overcharging or undercharging the system, both of which can negatively impact performance and even damage your air conditioning components.

Key Features of the S.U.R.&R AC412L
The S.U.R.&R AC412L boasts a range of features that make it a preferred choice for AC system servicing:
- In-line Design: The in-line design of the AC412L makes it easy to integrate into the existing AC system. This design minimizes the complexity of the installation process, saving time and effort during maintenance. This also reduces the chance of leaks and potential issues that may come with more complex valve designs.
- Low Side Compatibility: Specifically designed for use on the low side of AC systems, the AC412L allows for accurate pressure readings and safe servicing procedures. This specialized compatibility ensures the valve works effectively for its intended purpose.
- Durable Construction: Built with high-quality materials, the AC412L is designed to withstand the rigors of daily use. Its robust construction guarantees reliable performance over time. This durability reduces the frequency of replacement.
- 1/2" Size: The 1/2" size is a common size found in many automotive AC systems, ensuring wide compatibility.
Benefits of Using the S.U.R.&R AC412L
Choosing the S.U.R.&R AC412L offers numerous advantages that can significantly improve your AC system maintenance:
- Enhanced Efficiency: The in-line design simplifies the process of accessing the AC system, which increases the efficiency of repairs and maintenance tasks. Quick access points improve productivity in a professional setting.
- Accurate Diagnostics: Being on the low side, the valve enables accurate pressure readings, facilitating precise diagnostics and troubleshooting. Accurate readings are essential for identifying the source of a problem.
- Long-Term Reliability: The robust construction of the AC412L ensures a longer lifespan, reducing the need for frequent replacements. The long-term reliability provided by this valve helps to minimize system downtime.
- Cost-Effective Solution: The S.U.R.&R AC412L offers great value, combining high performance with an affordable price point. This affordability makes it suitable for both professional and DIY maintenance.
Product Specifications
Here's a detailed look at the technical specifications of the S.U.R.&R AC412L:
- Manufacturer: S.U.R.&R
- Part Number: AC412L
- Product Type: Service Port Valve
- Designated Size: 1/2"
- Application: Low Side of AC Systems
- Material: High-Quality, Durable Materials
- Country of Origin: USA
Installation Guide for the S.U.R.&R AC412L
Follow these steps for a proper installation of the S.U.R.&R AC412L:
- Preparation:
- Gather the necessary tools and materials, including the AC412L, appropriate wrenches, refrigerant recovery equipment (if applicable), and safety glasses.
- Ensure the AC system is depressurized using the correct refrigerant recovery procedures.
- Locate the existing low side service port on your AC system.
- Removal of the Old Valve (if applicable):
- Carefully remove the old valve, if replacing an existing one.
- Unscrew and remove the old service port valve using the appropriate wrench.
- Installation of the AC412L:
- Clean the threads of the existing port to ensure a good seal.
- Screw the S.U.R.&R AC412L into the low-pressure port, ensuring it is securely tightened. Do not overtighten.
- Use the appropriate wrench to tighten the valve, but avoid excessive force to prevent damage.
- Leak Test and System Recharge:
- Perform a leak test to verify that the valve is properly sealed. Use a leak detector or soapy water solution.
- If no leaks are detected, recharge the AC system with the appropriate refrigerant. Follow the manufacturer's recommended procedures for the specific refrigerant used in the system.
- Test the AC system for proper cooling performance after recharge.
- Safety Precautions:
- Always wear safety glasses during installation and servicing.
- Work in a well-ventilated area to avoid inhaling refrigerant.
- Follow all safety procedures and guidelines for working with refrigerants.
For optimal performance and safety, professional installation is recommended. You can purchase the S.U.R.&R AC412L at Dealershop USA.
Frequently Asked Questions (FAQ)
Here are some frequently asked questions about the S.U.R.&R AC412L:
- Q: Is the AC412L compatible with all air conditioning systems?
- A: The AC412L is designed for air conditioning systems that require a 1/2" low side service port valve. It is best to verify compatibility with your specific system requirements. Check the system's specifications or consult a professional if you're unsure.
- Q: Can the AC412L be used for high side applications?
- A: No, the AC412L is specifically designed for low side applications. For high side service port valves, consider models like the S.U.R.&R AC412H.
- Q: What materials are used in the construction of the AC412L?
- A: The AC412L is constructed with high-quality, durable materials that ensure reliable performance in demanding AC system environments. These materials are chosen for their resistance to corrosion and ability to withstand temperature and pressure fluctuations.
- Q: Where can I purchase the S.U.R.&R AC412L?
- A: You can purchase the S.U.R.&R AC412L directly from Dealershop USA. Dealershop USA is a trusted supplier of automotive repair products, and this valve can be easily added to your cart. They offer a wide selection of automotive parts and repair solutions.
- Q: How do I know if I need to replace my service port valve?
- A: Signs that you may need to replace your service port valve include refrigerant leaks, difficulty in getting accurate pressure readings, or visible damage to the valve. If you suspect a problem, a qualified technician can perform a diagnosis and confirm whether a replacement is necessary.
Conclusion
The S.U.R.&R AC412L 1/2" Low Side In-Line Service Port Valve is an essential component for anyone involved in the maintenance and repair of automotive air conditioning systems. With its in-line design, low side compatibility, and durable construction, it provides a reliable and efficient solution for accessing and servicing the low-pressure side of your AC system. This not only simplifies the maintenance process, but it also supports accurate diagnostics and improves the overall performance of your system. For those seeking to enhance their AC system's performance and longevity, the AC412L is a smart investment. Head over to Dealershop USA and buy the S.U.R.&R AC412L today!